"Just Like Being There"
Contiguous to One Wilshire
Building Features and Technical Specs |
Contact Info
Telecom Center LA is located directly adjacent to the One Wilshire Building, the largest carrier hotel in the Western United States.on the corner of 6th and Grand in the heart of the "Telecom District," in Downtown Los Angeles. South Grand Avenue is the main corridor for optical fiber cable in the downtown area making it the prime location for Carrier Hotels.
Telecom Center LA offers the widest possible array of connectivity options with high-bandwidth service available from numerous carriers and a direct conduit link of less than 500 linear feet to the One Wilshire "Meet-me Room."
| FEATURES AND TECHNICAL
SPECIFICATIONS |
| Connectivity |
Telecom Center LA offers the widest possible array of connectivity options with high-bandwidth service available from numerous carriers and a direct conduit link of less than 500 linear feet to the One Wilshire "Meet-me Room."
|
Network
Access
Center |
Connections to the One Wilshire "meet me Room" are provided through the second floor Network Access Center (NAC). The building provides customized cages and full or partial cabinets for tenant equipment. |
| HVAC |
Abundant cooling capacity is provided by 500 Ton redundant HVAC central plant, consisting of two-250 Ton Cooling Towers, Heat Exchanges and Water Pumps. The system is backed up with generator power.
|
| Electrical |
6000 amps, 277/480 Volt, 3-phase, and 4-wire electrical service, provided by two 3000 amp main distribution switch boards and bus ducts.
|
Emergency
Generators |
The electrical systems are backed up by three 2000KW diesel generators. Each generator has diesel fuel tanks.
|
| Risers/MPOE |
Due to the high number of telecommunications service providers in the building, there are multiple POE’s. A complex conduit system in both the horizontal and vertical spaces contributes to the robust infrastructure in the building, including three vertical risers thattraverse the building from the basement to the Penthouse (13 th floor) level. |
| Elevators |
Freight elevator capacity is 2,500 lbs |
| Engineers |
On-site operating engineers to support building systems and provide tenant service. |
Conditioned
Spaces |
- Cages of various sizes and entire suites available for turnkey POP solutions
- Building provides generator protected power, DC with battery and/or AC with UPS, protected cooling systems, fire suppression, cage construction and security systems
- Immediate occupancy – Carriers need only be concerned with equipment installation and network activation
- Conduit connectivity to the Meet Me Room
|
Standard
Telecom
Space |
- Shell Space for custom-builds currently available
- Connection to Building’s Generators
- Connection to Building’s Chilled Water System or Tenant may supply its own system
- Multiple building entrances and multiple fiber providers
- Conduit connectivity to the Meet Me Room
|

CONTACT
INFO:
The information
contained herein was obtained from third parties, and
it has not been independently verified by the real estate
brokers. Buyer/tenants should have the experts of their
choice inspect the property and verify all information.
Real estate brokers are not qualified to act as or select
experts with respect to legal, tax, environmental, building
construction, soils-drainage or other such matters.
|
|
|