freebsd.png






12,645 square feet

Telco/Data Facility

Building Features | Technical Specs
Floor Plan and Site Plan
Contact Info | Download PDF (658K)

1411 I Street is located in the center of one of the densest fiber networks in Northern California and an amenity rich Downtown core. With a 1909 glass and brick storefront, this property provides a stylish facade and an interior that was rebuilt in 2000, with 12,645 square feet of space, including 9,600 sf of raised floor data center space. The site has a secured private parking lot, redundant systems with standby generator, and secuirty via Card Key and pass code.

Current connectivity providers include Qwest, Worldcom/MCI, Surewest Broadband, Pacific Bell and Single Connect.

BUILDING FEATURES

  • Square Feet: 12,645
  • Floor Load: 100 lbs per sq. ft.
  • Ceiling Height: 9 feet from floor to the Unistrut Roof
  • Rights: Yes, with satellite space available NPA/NXX: 916-442, 447
  • Fiber: (2) fiber entry points # of Fiber Clients: (12) fiber entry points # of Fiber Interducts: (48) inner ducts, (4) one inch inner ducts/conduit
  • Fire Suppression System: Pre-action, dry pipe sprinkler system
  • HVAC: A/C units maintain a climate of 72 degrees and 30-60% humidity, N+1 redundancy
  • Power Reduncancy: Building power drawn from two substations
  • Standby Generator: Dedicated 750kW standby generator
  • Security Systems: Mantrap, Card Key Access, Alarm/Key Monitoring - CCTV Surveillance.
TECHNICAL SPECIFICATIONS
Equipment Area
  • 100 pounds per square foot load space
  • Roof rights with satellite space available
  • Ceiling height of 9’
  • Under-floor cooling provided by computer room equipment
  • Cooling not less than 150 BTU/h per square foot with an N+1 redundancy
  • Temperature is maintained at 70 degrees F by eight HVAC floor units
  • 50% ± 10% humidity non-condensing. Humidity control delivered through ATS units via infra-red humidifier.
  • Electrical Services
  • 1,200 amps at 480 volt total capacity, SMUD Power
  • 80 to 85 watts per square foot including HVAC
  • 100% Auto Start / Auto Transfer 750 KW Backup Generator
  • Fuel Tank, 1,000 gallons
  • 24 hour run time fuel capacity
  • Two hour response for fuel delivery
  • 150 kVA UPS System with 15 minute battery backup
  • UPS connected to backup power
  • 2800 amp, -480 volt DC Battery Capacity
  • 2 hour battery reserve non-redundant, 4 hours redundant
  • “True” A/B feeds
  • Security and Access:
  • Access to equipment area 24 hours, 7 days a week via card key and pass code
  • Non-secured personnel may enter the equipment area by escort only
  • Locking cabinets and cages
  • Full CCTV surveillance
  • Off-site monitoring by INTEG Systems
  • Secured, private parking lot
  • Fire Suppression System
  • Pre-action sprinkler rated for telecommunication equipment/computer room
  • Integrated smoke/heat detector system
  • Site monitoring by Simplex Grinnell
  • Space Options
  • 9,600 square feet of total floor space
  • Caged space within the facility
  • Open space for racks and/or cabinets
  • Separately demised (drywall) space available
  • Main computer room floor separate from rest of the building
  • Technician Room/Office available for use by all customers
  • Under floor leak detection system
  • Seismic cabinets and bracing used on all installations
  • Bundled Cabinet/power configurations available
  • Managed services and storage solutions offered through partner companies
  • Connectivity
  • The following providers are currently installed: o Qwest
    o Worldcom/MCI
    o Surewest Broadband
    o Pacific Bell
    o Single Connect
  • Telecom Services
  • Diverse Fiber/Cable building entrances
  • Total of 8 four inch conduits with 4 inner-ducts from each entrance
  • Overhead cable trays are provided for connectivity
  • Communication cable is isolated from power cables
  • POTS/DSI/DS3/OC-X circuits available

  • CONTACT INFO:

    Grubb & Ellis Company
    Dan Chamberlain (916) 418-6026
    Steve Griffin (916) 418-6018
    1610 Arden Way, Ste. 195,
    Sacramento, CA 95815
    Phone: (916) 418.6000
    Fax: (916) 418-0231

    The information contained herein was obtained from third parties, and it has not been independently verified by the real estate brokers. Buyer/tenants should have the experts of their choice inspect the property and verify all information. Real estate brokers are not qualified to act as or select experts with respect to legal, tax, environmental, building construction, soils-drainage or other such matters.

    © 2000 Carrier Hotels, Inc.
    116 Village Boulevard, Suite 200
    Princeton, NJ 08540
    Phone:(609) 243-7525