12,645
square feet
Telco/Data
Facility

Building Features
| Technical Specs
Floor Plan and Site Plan
Contact Info | Download
PDF (658K)
1411
I Street
is located
in the center of one of the densest fiber networks in
Northern California and an amenity rich Downtown core.
With a 1909
glass and brick storefront, this property provides a
stylish facade
and an interior that was rebuilt in 2000, with 12,645
square feet of space, including 9,600 sf of raised floor
data center space.
The site has a
secured private parking lot, redundant systems with
standby generator, and secuirty via Card Key and pass
code.

Current connectivity providers include Qwest, Worldcom/MCI,
Surewest Broadband, Pacific Bell and Single Connect.

BUILDING
FEATURES
- Square
Feet: 12,645
- Floor
Load: 100 lbs per sq. ft.
- Ceiling
Height: 9 feet from floor to the Unistrut Roof
- Rights:
Yes, with satellite space available NPA/NXX: 916-442,
447
- Fiber:
(2) fiber entry points # of Fiber Clients: (12) fiber
entry points # of Fiber Interducts: (48) inner ducts,
(4) one inch inner ducts/conduit
- Fire
Suppression System: Pre-action, dry pipe sprinkler
system
- HVAC:
A/C units maintain a climate of 72 degrees and 30-60%
humidity, N+1 redundancy
- Power
Reduncancy: Building power drawn from two substations
- Standby
Generator: Dedicated 750kW standby generator
- Security
Systems: Mantrap, Card Key Access, Alarm/Key Monitoring
- CCTV Surveillance.
| TECHNICAL
SPECIFICATIONS |
| Equipment
Area |
100
pounds per square foot load space
Roof
rights with satellite space available
Ceiling
height of 9’
Under-floor
cooling provided by computer room equipment
Cooling
not less than 150 BTU/h per square foot with an
N+1 redundancy
Temperature
is maintained at 70 degrees F by eight HVAC floor
units
50%
± 10% humidity non-condensing. Humidity control
delivered through ATS units via infra-red humidifier.
|
| Electrical
Services |
1,200
amps at 480 volt total capacity, SMUD Power
80
to 85 watts per square foot including HVAC
100%
Auto Start / Auto Transfer 750 KW Backup Generator
Fuel
Tank, 1,000 gallons
24
hour run time fuel capacity
Two
hour response for fuel delivery
150
kVA UPS System with 15 minute battery backup
UPS
connected to backup power
2800
amp, -480 volt DC Battery Capacity
2
hour battery reserve non-redundant, 4 hours redundant
“True”
A/B feeds
|
| Security
and Access: |
Access
to equipment area 24 hours, 7 days a week via
card key and pass code
Non-secured
personnel may enter the equipment area by escort
only
Locking
cabinets and cages
Full
CCTV surveillance
Off-site
monitoring by INTEG Systems
Secured,
private parking lot
|
| Fire
Suppression System |
Pre-action
sprinkler rated for telecommunication equipment/computer
room
Integrated
smoke/heat detector system
Site
monitoring by Simplex Grinnell
|
| Space
Options |
9,600
square feet of total floor space
Caged
space within the facility
Open
space for racks and/or cabinets
Separately
demised (drywall) space available
Main
computer room floor separate from rest of the
building
Technician
Room/Office available for use by all customers
Under
floor leak detection system
Seismic
cabinets and bracing used on all installations
Bundled
Cabinet/power configurations available
Managed
services and storage solutions offered through
partner companies
|
| Connectivity |
The
following providers are currently installed: o
Qwest
o
Worldcom/MCI
o Surewest Broadband
o Pacific Bell
o Single Connect
|
| Telecom
Services |
Diverse
Fiber/Cable building entrances
Total
of 8 four inch conduits with 4 inner-ducts from
each entrance
Overhead
cable trays are provided for connectivity
Communication
cable is isolated from power cables
POTS/DSI/DS3/OC-X
circuits available
|
CONTACT
INFO:
Grubb
& Ellis Company
Dan Chamberlain (916) 418-6026
Steve Griffin (916) 418-6018
1610 Arden Way, Ste. 195,
Sacramento, CA 95815
Phone: (916) 418.6000
Fax: (916) 418-0231
|
The information
contained herein was obtained from third parties, and
it has not been independently verified by the real estate
brokers. Buyer/tenants should have the experts of their
choice inspect the property and verify all information.
Real estate brokers are not qualified to act as or select
experts with respect to legal, tax, environmental, building
construction, soils-drainage or other such matters.
|